- ; Oberon Terminal Emulator/2 Initialization File
- ;
- ; Contents Copyright 1990-1991, Oberon Software, Mankato, MN 56001
-
- ;
- ; Sample TE/2 Initialization File
- ;
- ; In most cases the settings you will find here just duplicate the
- ; built-in defaults that TE/2 would use anyway. We've tried to
- ; place an example of every possible setting for this file in here
- ; though so you may easily customize your installation of TE/2.
- ;
-
- ;Comm Port Settings
- ;==================
-
- Baud 2400
- ; Type: numeric, must be a valid baud rate
- ; Notes: this will become the default baud rate when TE/2
- ; first enters terminal mode.
-
- BreakLen 1000 ;milliseconds
- ; Type: numeric, greater than zero
- ; Notes: Break signal duration in milliseconds
-
- CtsRts BOTH
- ; Type: enumeration, CTS, RTS, BOTH, or NEITHER
-
-
- ; Device com1
- ; Type: simple string, rules for modem strings apply
- ; Notes: The "Device" parameter may override any "Port"
- ; parameter given in the file. You do not have
- ; to specify "com1", "com2", et cetera. If your
- ; comm device has another name however the Alt-I
- ; information display will not match the reality
- ; when you use the "Device" parameter unless it
- ; is named "com1", "com2", etc., and the "Port"
- ; parameter is set to match.
-
- Parity N
- ; Type: enumerated, must be N, O, E, M, or S
- ; Notes: this will become the default parity when TE/2
- ; first enters terminal mode.
-
- Port 1
- ; Type: numeric, must be 1, 2, ..., 8
- ; Notes: If your comm device is named "comX" where X is
- ; a number from 1 to 8, you do not need to use
- ; the "Device" parameter (above) and may simply
- ; specify the port number.
-
- StopBits 1
- ; Type: enumerated, must be 1, 1.5, or 2
- ; Notes: this will become the default number of stop bits
- ; when TE/2 enters terminal mode.
-
- WordLen 8
- ; Type: numeric, must be 7 or 8
- ; Notes: this will become the default word length when TE/2
- ; first enters terminal mode.
-
- XonXoff neither
- ; Type: enumerated, NEITHER, TRANSMIT, RECEIVE, or BOTH
-
-
- ;Terminal Emulation Settings
- ;===========================
-
- Emulate ANSI_TE2
- ; Type enumerated, must be TTY, ANSI, ANSI_TE2, VT100, or 3101
- ; Note: defines the default terminal emulation package at
- ; programs startup. Default, if omitted, is ANSI_TE2
-
- enqReply ; NULL
- ; Type: modem string
- ; Notes: in VT100 mode, this string will be sent to the
- ; remote system in response to an ENQ character
-
- AutoNL3101 false
- ; Type: true/false
- ; Notes: Enables/disables Auto-Newline Mode in the IBM 3101 emulation
-
- AutoLF3101 false
- ; Type: true/false
- ; Notes: Enables/disables Auto-Linefeed Mode in the IBM 3101 emulation
-
- Scroll3101 false
- ; Type: true/false
- ; Notes: Enables/disables Auto-Scroll Mode in the IBM 3101 emulation
-
-
- ;Terminal Settings
- ;=================
-
- alarmPopUp true ;NOTE default is: false
- ; Type: true/false
- ; Notes: enables/disable alarm pop-up screens. Further,
- ; note that the alarm pop-up will only ever be
- ; displayed if TE/2 is not the foreground task
- ; at the time of the alarm.
-
- alarmTime 2 ;seconds
- ; Type: numeric, must be greater than or equal to zero
- ; Notes: Alarm duration in seconds, zero disables the alarm
-
- AlarmType CHIME
- ; Type: enumerated: NONE, CHIME, or BUZZER
- ; Notes: Determines how the alarm will sound
-
- chatBuffered true
- ; Type: true/false
- ; Notes: entry value for chat mode buffering
-
- ClsReset false
- ; Type: true/false
- ; Notes: If set to true will cause Alt-C and CLS() to reset
- ; the terminal attribute to the default (TermAttr)
- ; before clearing the screen. Default, if omitted,
- ; is false.
-
- colorLock false
- ; Type: true/false
- ; Notes: if true the terminal color cannot be changed via
- ; ANSI codes from the remote
-
- dtrHangUp true
- ; Type: true/false
- ; Notes: determines whether the hangup sequence also drops
- ; DTR momentarily
-
- LFafterCR false
- ; Type: true/false
- ; Notes: entry value for LF After CR
-
- LocalEcho false
- ; Type: true/false
- ; Notes: entry value for Local Echo
-
- LogoDelay 8 ;seconds
- ; Type: numeric, greater than or equal to zero
- ; Notes: Length of time the TE/2 logo will remain on screen
- ; after primary initialization has completed. If this
- ; is set to zero, the logo will not be displayed.
-
- MatchBaud true
- ; Type: true/false
- ; Notes: if false the dialer will not attempt to match the
- ; baud rate after making a connection. Use this if
- ; you need to "Lock" the baud rate for a high-speed
- ; connection.
-
- MenuActive true
- ; Type: true/false
- ; Notes: initial display/nondisplay of Terminal Modem menu
-
- QueryHangUp true ;NOTE default is:false
- ; Type: enumerated: TRUE, FALSE, IFCARRIER
- ; Notes: If TRUE, TE/2 will ask for verification each time
- ; before hanging up or exiting. If FALSE, TE/2 will
- ; never ask for verification. If IFCARRIER, TE/2
- ; will ask only if it is currently on-line.
-
- ; ScreenLines 25 ;NOTE if absent will default to the number of
- ; ; of lines in the current screen mode
- ; Type: numeric, must be greater than zero
- ; Notes: This sets the desired number of lines for the
- ; screen.
-
- ScrollBack 250 ;lines
- ; Type: number, greater than or equal to zero
- ; Notes: Number of lines to retain in Scroll Back Buffer,
- ; if this is set to zero the Scroll Back Buffer is
- ; disabled.
-
-
- ;Modem Settings
- ;==============
-
- ; Connect special
- ; Type: modem string(s)
- ; Notes: You may have up to 12 connect strings specified.
- ; These are the actual strings that TE/2's dialer
- ; will look for from the modem when it dials. Each
- ; string follows the rules for modem strings given
- ; above and is followed by a comma and a baud rate
- ; which will be used for purposes of baud matching
- ; if you have MatchBaud set on.
- ; Example: This is an example of setting several connect
- ; strings in TE2.INI:
- ;
- ; Connect CONNECT^M,300
- ; Connect CONNECT_1200,1200
- ; Connect CONNECT_2400,2400
- ; Connect CONNECT_9600/ARQ,9600
- ; Note that if you specify any Connect strings you
- ; should be sure to specify ALL Connect strings
- ; you expect to encounter. TE/2 default set covers
- ; 300, 1200, 2400, 4800, and 9600 for standard
- ; Hayes compatible modems operating with verbal
- ; response codes. If you specify any Connect strings
- ; in TE2.INI however, TE/2 assumes that you will
- ; specify them all.
- ; Further Note: The strings are searched in order from
- ; first to last and when one matches the search ends.
- ; Thus, the "^M" in the first example is very
- ; important! If it were not there, any string which
- ; begins with "CONNECT" (i.e., every modem connect
- ; result string!) would be taken to imply 300 baud.
- ; This is probably not what you had in mind.
- ; Also, the third line above will match
- ; "CONNECT 2400^M" as well as "CONNECT 2400/ARQ^M",
- ; but the fourth line will not match "CONNECT 9600^M".
-
- Connect CONNECT^M,300
- Connect CONNECT_1200,1200
- Connect CONNECT_2400,2400
- Connect CONNECT_4800,4800
- Connect CONNECT_9600,9600
-
-
- modemAnsStrg ATS0=1^M^J
- ; Type: modem string
- ; Notes: this string is used to initialize auto-answer
- ; mode.
- ; Note further: This string is not used in this version
- ; of TE/2 but to ensure file compatibility
- ; with the full version, it is included here.
-
- modemDelayChar 0x7e,500
- ; Type: special
- ; Notes: The two values here are the ascii value of the
- ; character to use for delays in the various modem
- ; strings (0x7e is the tilde character "~") and the
- ; duration of the delay in milliseconds
-
- modemDialStrg ATDT
- ; Type: modem string
- ; Notes: this is used as the modem dial command
-
- modemDialSufx ^M
- ; Type: modem string
- ; Notes: this is sent to the modem after the number in a
- ; dial command
-
- modemHangStrg ~~~+++~~ATH0^M^J
- ; Type: modem string
- ; Notes: this string is sent to the modem to cause it to
- ; hang-up the line (see also dtrHangUp)
-
- modemInitStrg ATE0_M1_Q0_V1_X4_S7=255_S11=55_S0=0^M^J
- ; Type: modem string
- ; Notes: this string is sent to the modem at startup for
- ; initialization
-
- modemOKStrg OK
- ; Type: modem string
- ; Notes: this is the string that TE/2 will expect the modem
- ; to return after receiving a command string
- ; successfully.
-
- ; noConnect special
- ; Type: modem string(s)
- ; Notes: See also "Connect" above. Here you may specify up
- ; to 6 NoConnect strings. These are the strings
- ; which TE/2's dialer will look for when dialing to
- ; signal that the dialing attempt has failed. These
- ; strings follow the rules for modem strings given
- ; above. If you specify any NoConnect strings you
- ; must specify every one you expect to encounter
- ; because you will be replacing TE/2's default set.
- ;
- ; TE/2's default set is:
- NoConnect NO_CARRIER
- NoConnect ERROR
- NoConnect NO_DIAL_TONE
- NoConnect BUSY
- NoConnect NO_ANSWER
- NoConnect VOICE
-
-
-
- ;Dialer and Dialing Directory
- ;============================
-
- AutoDirSave true ;NOTE default is: false
- ; Type: true/false
- ; Notes: if true the directory file will be saved each time
- ; upon exiting the Dialing Directory.
-
- dialerTimeOut 45 ;seconds
- ; Type: numeric, greater than zero
- ; Notes: Amount of time in seconds that the dialer will
- ; allow a phone number to ring.
-
- RedialDelay 2 ;seconds
- ; Type: numeric, greater than zero
- ; Notes: Amount of time in seconds that the dialer will
- ; pause between dialing attempts.
-
-
- ;Color Attributes
- ;================
-
- ; This is the color setup that the author uses. They should be
- ; fairly reasonable in full screen mode and need some readjustment
- ; if you run in a vio window.
-
- ChatAttr 0x0b ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Chat Mode, Local Window text
-
- ChatRemoteAttr 0x03 ;NOTE default is: 0x07 - White on black
- ; Type: attribute
- ; Notes: Chat Mode, Remote Window text
-
- ChatTitleAttr 0x30 ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Chat Mode, titles
-
- DLogDaAttr 0x28 ;NOTE default is: 0x08 - Gray on black
- ; Type: attribute
- ; Notes: Dialog boxes, disabled menu items
-
- DLogEdAttr 0x02 ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Dialog boxes, text input, while editing
-
- DLogEdHiAttr 0x70 ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Dialog boxes, text input, initial display of
- ; default value
-
- DLogHiAttr 0x2f ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Dialog boxes, highlit text
-
- DLogNormAttr 0x20 ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Dialog boxes, normal text
-
- DialHiAttr 0x0e ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Dialing Directory, highlighted bar
-
- DialNormAttr 0x03 ;NOTE default is: 0x07 - White on black
- ; Type: attribute
- ; Notes: Dialing Directory, normal text
-
- ErrorAttr 0x4f ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Error Message display
-
- LogoAttr 0x1f ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Terminal Screen menu, TE/2 logo
-
- MenuHiAttr 0x0e ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Terminal Screen menu, highlit text
-
- MenuNormAttr 0x03 ;NOTE default is: 0x07 - White on black
- ; Type: attribute
- ; Notes: Terminal Screen menu, normal text
-
- ScrlBackAttr 0x03 ;NOTE default is: 0x07 - White on black
- ; Type: attribute
- ; Notes: Scroll Back, normal text
-
- ScrlBackFdAttr 0x4f ;NOTE default is: 0x0f - Bright white on black
- ; Type: attribute
- ; Notes: Scroll Back, found text
-
- ScrlBackMkAttr 0x13 ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Scroll Back, marked text
-
- ScrlBackTiAttr 0x30 ;NOTE default is: 0x70 - Black on white
- ; Type: attribute
- ; Notes: Scroll Back, titles
-
- ShadowAttr 0x08 - Gray on black
- ; Type: attribute
- ; Notes: Dialog boxes, shadow
-
- SnapShotAttr 0x70 - Black on white
- ; Type: attribute
- ; Notes: SnapShot, flash attribute
-
- TermAttr 0x07 - White on black
- ; Type: attribute
- ; Notes: Terminal Screen attribute
-
-
-
- ;Transfer Protocols
- ;==================
-
- AsciiUL 0,crlf,true,0,0,false,false,2000,2000
- ; Type: special
- ; Notes: Here you may specify the default answers to the
- ; questions posed in the Ascii Upload Dialog (see
- ; "Alt-U Upload" above). The last two fields are
- ; options, all others must be specified, they must
- ; be separated by commas, and there must be NO
- ; extra space or tab characters in the line.
- ; The fields are:
- ; Prompt Char: ascii value of the prompt character
- ; you wish to use. The value may be
- ; in decimal, hex, or octal. Use zero
- ; to set no prompt.
- ; CR before LF: "LF", "CR", or "CRLF"
- ; Expand Blanks Lines: true or false.
- ; Char Pacing: in milliseconds.
- ; Line Pacing: in milliseconds.
- ; Strip 8th Bit: true or false.
- ; View Output: true or false.
- ; Write Timeout: in milliseconds.
- ; Read Timeout: in milliseconds.
-
- AutoZM true ;NOTE default is: false
- ; Type: true/false
- ; Notes: enables/disables Auto ZModem downloads
- ; When enabled, TE/2 will automatically begin a ZModem
- ; download whenever it receives the ZModem signature
- ; from the remote system.
-
- ClobberDL SALVAGE
- ; Type: enumerated: TRUE, FALSE, or SALVAGE
- ; Notes: This controls what TE/2 will do when you attempt to
- ; download a file with a file of the same name already
- ; in existence in the download directory of your disk.
- ; If set to TRUE, the new file will overwrite (clobber)
- ; the old file, if set to FALSE it will abort the
- ; transfer and issue an error message. If set to
- ; SALVAGE, it will attempt to rename the existing file
- ; before beginning to write the new file. It does
- ; this by replacing characters in the file name,
- ; starting at the end of the name, with dollar sign
- ; characters until it finds a name that does not already
- ; exist.
-
- downloadPath ; NULL
- ; Type: path name
- ; Notes: specifies the directory you wish all downloaded
- ; files to be placed in. If left NULL, the current
- ; directory is used. For XModem and XModem-1K you
- ; may override this setting by specifying a drive or
- ; a path when prompted for the file name.
-
- DLPrtyClass FIXEDHIGH,0
- ; Type: special
- ; Notes: specifies the priority you wish OS/2 to give the
- ; download file transfer protocols while they are
- ; doing their duties. TE/2 normally operates at the
- ; default priority level but if the DLPrtyClass is
- ; set to anything other than "NORMAL" it will adjust
- ; the priority level accordingly for the duration of
- ; the file transfer and restore normal priority upon
- ; return. Valid values for the first parameter of
- ; DLPrtyClass are: "NORMAL", "FIXEDHIGH", or
- ; "TIMECRITICAL". The second parameter is called a
- ; priority delta, it may be in the range of -31 to 31
- ; and it may be omitted with no ill effects.
- ; Further Notes: If you set the priority class to NORMAL you
- ; may very well experience timeout errors during your
- ; file transmissions especially if your computer is
- ; busy with other tasks while the file is transferring.
- ; One the other hand, if you leave it at the default
- ; value of FIXEDHIGH and are still experiencing these
- ; problems you might want to set TIMECRITICAL although
- ; the response and throughput of all other processes
- ; running on your computer during the transfer will
- ; become noticeably slower.
-
- ULPrtyClass FIXEDHIGH,0
- ; Type: special
- ; Notes: See DLPrtClass above for a full discussion of how to
- ; set this variable. ULPrtyClass affects upload file
- ; transfers in exactly the same manner as DLPrtyClass
- ; affects downloads.
-
- uploadPath ; NULL
- ; Type: path name
- ; Notes: This is where TE/2 will look for a file that does
- ; not have a drive or path specified explicitly in
- ; its name. If left to NULL this will be the current
- ; directory.
-
-
- ;Misc File and Path Specs
- ;========================
-
- CallLog ; NULL
- ; Type: path name
- ; Notes: If this file name is specified, TE/2 will write
- ; information about each outgoing phone call it
- ; makes. The information is the Name from the
- ; directory entry (or the number for a manual dial),
- ; the time the call began, the time it ended, and
- ; the total call duration. This is handy for what-
- ; ever record keeping you need to do whether it's
- ; for tax purposes or just to keep the phone company
- ; honest.
-
- SnapShot te2snap.sht
- ; Type: path name
- ; Notes: This specifies the name of the snapshot file (see
- ; "Alt-S SnapShot" above).
-
- logPath ; NULL
- ; Type: path name
- ; Notes: This is where TE/2 will place all log files (see
- ; "Alt-L LogFile") unless you specify a name with
- ; an explicit drive or path when prompted for a
- ; log file name.
-
- ShellCmd cmd.exe ; ,NULL
- ; Type: special
- ; Notes: This specifies the name of the program which is to
- ; be executed when you use the Alt-O key (see "Alt-O
- ; Shell to OS/2" above). The program name should be
- ; a complete path/spec and contain the file extension
- ; (".exe", etc.). If parameters are needed they may
- ; be specified after one or more white space
- ; characters (space or tab). The parameter string
- ; follows the rules for modem strings given above.
- ; That is, space characters must be replaced with
- ; underscores, et cetera.
- ; Note that to execute a batch file (".cmd") you must
- ; use the syntax:
- ; ShellCmd cmd.exe /c_cmdfilename
-
-